HOW HPLC WORKS - AN OVERVIEW

how HPLC works - An Overview

how HPLC works - An Overview

Blog Article

I want to join newsletters from Sartorius (Sartorius AG and its affiliated companies) centered of my own passions.

각각 다른 산업 분야에 대한 자세한 정보 및 다양한 카테고리는 다음 써모 피셔 사이언티픽 학습 센터에서 산업 및 응용 과학 페이지를 확인하세요.

In advance of employing a mobile period solvent we have to get rid of dissolved gases, which include N2 and O2, and small particulate issue, like dust. Mainly because You will find a significant fall in stress over the column—the force for the column’s entrance is up to many hundred atmospheres, however it is atmospheric tension within the column’s exit—gases dissolved from the mobile stage are launched as gasoline bubbles that could interfere Along with the detector’s reaction.

- 분석결과는 재현성이 우수하며, 특히 오토샘플러 등을 사용함으로써 보다 높은 재현성을 확보할 수 있어 생산성을 한층 더 향상시킬 수 있습니다.

Numerous other detectors are actually Utilized in HPLC. Measuring a adjust inside the mobile stage’s refractive index is analogous to monitoring the cellular section’s thermal conductivity in gas chromatography. A refractive index detector is sort of common, responding to Virtually all compounds, but has a relatively bad detection limit of 0.

カラム周辺の温度の変動によって溶出時間が安定せず再現性が悪くなる場合があるため、カラム温度を一定に保つために使用する。またカラム温度を分離条件のパラメーターの一つとして積極的に利用する場合もある。

-hydroxybenzoic acid (PH) on a nonpolar C18 column topic to some maximum analysis time of six min. The shaded areas signify locations in which a separation is impossible, with the unresolved solutes determined.

Next, a lot of the compounds inside the serum may possibly soak up too strongly to the stationary stage, degrading the column’s performance. Finally, Whilst an HPLC can independent and review advanced mixtures, an Examination is tough check here if the quantity of constituents exceeds the column’s peak ability.

스포츠 도핑에서 약물 검사까지 법의독성학 응용 분야에 적용되는 방법에 대해 알아보세요.

). If the detector is a diode array spectrometer, then we can also Screen The end result as a three-dimensional chromatogram that reveals absorbance to be a perform of wavelength and elution time.

*본 포스팅의 저작권은 써모 피셔 사이언티픽에 있으며, 콘텐츠의 무단 복제 및 수정, 재배포를 금지합니다.

, for instance, exhibits retention moments for four weak acids in two mobile phases with approximately identical values for (P^ primary ). Although the get of elution is the same for both of those cell phases, each solute’s retention time is affected otherwise by the selection of organic and natural solvent.

Mobile phase impurities: Contaminants in the cellular period can elute with the column and show up as ghost peaks. Prepare a fresh mobile period with high-purity solvents and consider filtering the cell period in advance of use.

, which happens to be the greater frequent type of HPLC, the stationary section is nonpolar and also the cell stage is polar. The most typical nonpolar stationary phases use an organochlorosilane exactly where check here the R team is undoubtedly an n